Show simple item record

dc.contributor.advisorJohn Christenson
dc.contributor.advisorJean Smith
dc.contributor.advisorArthur Westwell
dc.contributor.authorMurphy, John
dc.date.accessioned2020-04-30T10:04:23Z
dc.date.available2020-04-30T10:04:23Z
dc.date.issued1974-04-01
dc.identifier.urihttps://scholars.carroll.edu/handle/20.500.12647/3270
dc.description.abstractA new method for testing the acceptability of metal tooth implants as an alternative to oral cavity implantation is described. Various metals were successfully implanted into the back tissue of Balb/C mice. Aluminum and copper implants were rejected, exhibiting discoloration and thickening of the tissues. Vitallium, titanium, gold alloy, silver, iron and lead were accepted
dc.titleAn Evaluation Of Various Metal Tooth Implants In Balb/C Mice
dc.typethesis
carrollscholars.object.degreeBachelor's
carrollscholars.object.departmentLife & Environmental Sciences
carrollscholars.object.disciplinesPlastic Surgery; Surgery
carrollscholars.legacy.itemurlhttps://scholars.carroll.edu/lifesci_theses/528
carrollscholars.legacy.contextkey12843730
carrollscholars.object.seasonSpring
dc.date.embargo12/31/1899 0:00


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record